Prepare for the accuracy check of the reference nozzle with ACP.Perform accuracy check of the reference nozzle with ACPCheck the value of AMF Index Save the measured result of the mounting accuracy Save the data as the accuracy before adjustment after relocation of the machine. Does the value of AMF Index meet the specification? OK Complete mounting adjustment NGPerform adjustment of the reference nozzle with ACP Please refer to “6.1. The workflow when “AMF Index” falls below 1.000”- Camera scale of the fiducial camera- The camera scale of the scan camera- Positioning of the scan camera-Head Offset XY Check the value of “AMF Index” after adjustment. Does the value meet the specification? NGInvestigate the cause ofthe problem Save the value as the accuracy after adjustment. Save the result of the mounting accuracy after adjustment. - Check if the board is transferred from the upstream machine to the down stream machine smoothly.- Check the pickup position of the feeder plate.- Check the operation of the blow station.- Check the “PCB origin”.- Check the vacuum level.- Check the operation of the “Nozzle change”function (Option) Check the accuracy of the multi camera and perform adjustment (Option)