After the required clamping voltage is determined and potential components are selected, simulate the lightning transients applied to the protection circuit and the circuit being protected using a circuit simulator. Then, using data from the simulation, the transients to which each component in the protection circuit are exposed are transformed into all the reference transients typically used by the component datasheets.