1.1 Test setup for the test “harmonic current emissions”.The test setup is given in IEC 61000-3-2 and IEC 61000-4-7.1.2 EquipmentThe test can be done at different workplaces with the associated equipment. Every of the listed power source can be used. The tests of the harmonic current emissions have to be done with the power analyser. The Thermometer/Hygrometer is mounted in the room. The used equipment is documented in the test report.