We have 142 finished products of 61-i66s4-00-2.After receiving the feedback from your company, I, technology and quality randomly selected one product from the inventory for flatness measurement. The measurement result shows that the 100um feeler gauge cannot pass. The drawing requires that the surface flatness range is 0 ~ + 120um