顶棚内饰板转弯处弧度小,无法与文件柜有效搭接。左下裙板搭接处结构复杂,造成间隙原因基本为零部件累计公差造成。1、储物箱右侧挡板背面缺少支撑,的英语翻译

顶棚内饰板转弯处弧度小,无法与文件柜有效搭接。左下裙板搭接处结构复杂,

顶棚内饰板转弯处弧度小,无法与文件柜有效搭接。左下裙板搭接处结构复杂,造成间隙原因基本为零部件累计公差造成。1、储物箱右侧挡板背面缺少支撑,挡板向内凹陷。2、零部件变形:塑料挡板变形,向内凹陷与地板皮间隙大。仪表台副驾驶处骨架卡接点偏低,卡固后与仪表台本体间隙大线束分支处防护强度不足,线束端子缺少防护雨刮臂喷淋水管插接位置缩紧力度不足,插接后松动,喷淋时漏水。示廓灯与线束插接到位后不亮,用力推动线束后灯亮,松手后熄灭。初步分析为灯与线束端子接触不实。车门控制开关分装时未将四个安装孔全部卡入螺母,气动工具冲击力强,导致螺母座变形。
0/5000
源语言: -
目标语言: -
结果 (英语) 1: [复制]
复制成功!
The curvature of the ceiling trim panel is small and cannot be effectively overlapped with the filing cabinet. <br>The overlapping structure of the lower left skirt board is complicated, and the reason for the gap is basically caused by the cumulative tolerance of the parts. <br>1. The back of the right side baffle of the storage box lacks support, and the baffle is recessed inward. <br>2. Deformation of components: the plastic baffle is deformed, and the gap between the inward depression and the floor skin is large. <br>The skeleton clamping point of the co-pilot at the instrument panel is low, and the <br>protective strength at the branch of the wiring harness with a large gap between the instrument panel after clamping is insufficient <br>. Water leaks when spraying. <br>The profile light and the harness are not lit after they are inserted into place. The light is turned on when the harness is pushed hard, and it goes out when you let go. The preliminary analysis is that the lamp is not in proper contact with the harness terminal. <br>When the door control switch is sub-assembled, all four mounting holes are not snapped into the nut. The impact force of the pneumatic tool is strong, resulting in deformation of the nut seat.
正在翻译中..
结果 (英语) 2:[复制]
复制成功!
The roof interior panel has a small arc at the turn and cannot be properly connected to the filing cabinet.<br>The structure of the lower left apron is complex, causing the gap to be caused by the cumulative tolerance of the components.<br>1, the storage box right side of the back of the bezel lack of support, bezel inward depression.<br>2, parts deformation: plastic bezel deformation, to the inward depression and floor skin gap large.<br>The skeleton card connection at the vice-driver of the instrument station is low, and the gap between the gauge table body is large after the card is secured.<br>Insufficient protection at the harness branch, lack of protection at the harness terminals<br>Wiper arm spray water pipe insertion position tension is insufficient, after insertion loose, spray water leakage.<br>The profile light and the harness are not lit when plugged into the position, push the rear light of the harness to light, and turn off after loosening your hand. The preliminary analysis indicates that the contact between the lamp and the harness terminal is not true.<br>The door control switch was not divided into the nut all four mounting holes, the pneumatic tool impact force is strong, resulting in the nut seat deformation.
正在翻译中..
结果 (英语) 3:[复制]
复制成功!
The turning part of the ceiling interior trim panel has a small radian and cannot be effectively overlapped with the filing cabinet.<br>The structure of the lap joint of the left lower apron is complex, and the gap is basically caused by the accumulated tolerance of the parts.<br>1. The back of the baffle on the right side of the storage box lacks support and the baffle is sunken inward.<br>2. Deformation of parts: the plastic baffle is deformed, and the gap between the inward depression and the floor skin is large.<br>The frame of the front passenger's seat of the instrument panel is on the low side, and the gap between the frame and the instrument panel body is large after being clamped<br>The protection strength at the branch of harness is insufficient, and the harness terminal is lack of protection<br>The tightening force of the spray water pipe of the wiper arm is insufficient. It is loose after plugging, and water leaks during spraying.<br>After the clearance lamp and harness are inserted in place, they do not light up. Push the harness hard and the lamp will light up, and then it will go out. The preliminary analysis shows that the contact between the lamp and the harness terminal is not true.<br>When the door control switch is assembled separately, the four mounting holes are not all clamped into the nuts. The impact force of the pneumatic tools is strong, resulting in the deformation of the nut seat.<br>
正在翻译中..
 
其它语言
本翻译工具支持: 世界语, 丹麦语, 乌克兰语, 乌兹别克语, 乌尔都语, 亚美尼亚语, 伊博语, 俄语, 保加利亚语, 信德语, 修纳语, 僧伽罗语, 克林贡语, 克罗地亚语, 冰岛语, 加利西亚语, 加泰罗尼亚语, 匈牙利语, 南非祖鲁语, 南非科萨语, 卡纳达语, 卢旺达语, 卢森堡语, 印地语, 印尼巽他语, 印尼爪哇语, 印尼语, 古吉拉特语, 吉尔吉斯语, 哈萨克语, 土库曼语, 土耳其语, 塔吉克语, 塞尔维亚语, 塞索托语, 夏威夷语, 奥利亚语, 威尔士语, 孟加拉语, 宿务语, 尼泊尔语, 巴斯克语, 布尔语(南非荷兰语), 希伯来语, 希腊语, 库尔德语, 弗里西语, 德语, 意大利语, 意第绪语, 拉丁语, 拉脱维亚语, 挪威语, 捷克语, 斯洛伐克语, 斯洛文尼亚语, 斯瓦希里语, 旁遮普语, 日语, 普什图语, 格鲁吉亚语, 毛利语, 法语, 波兰语, 波斯尼亚语, 波斯语, 泰卢固语, 泰米尔语, 泰语, 海地克里奥尔语, 爱尔兰语, 爱沙尼亚语, 瑞典语, 白俄罗斯语, 科西嘉语, 立陶宛语, 简体中文, 索马里语, 繁体中文, 约鲁巴语, 维吾尔语, 缅甸语, 罗马尼亚语, 老挝语, 自动识别, 芬兰语, 苏格兰盖尔语, 苗语, 英语, 荷兰语, 菲律宾语, 萨摩亚语, 葡萄牙语, 蒙古语, 西班牙语, 豪萨语, 越南语, 阿塞拜疆语, 阿姆哈拉语, 阿尔巴尼亚语, 阿拉伯语, 鞑靼语, 韩语, 马其顿语, 马尔加什语, 马拉地语, 马拉雅拉姆语, 马来语, 马耳他语, 高棉语, 齐切瓦语, 等语言的翻译.

Copyright ©2024 I Love Translation. All reserved.

E-mail: