earthing system, as applicable, relevant connections accessories, hermatically sealed category B capacitors, terminals, lugs, protective devices and boxes, lamps/light sources, ballasts/drivers, transformers, ignitors, etc. and all luminaire components, junction boxes, internal wiring from junction box to and between luminaires components, aiming and adjustment, spare parts (lamps, control gear, etc.) as specified. 1.06 Rates for lighting columns / poles are deemed to include: lighting fixture / luminaires including lamps / light sources, control gear / drivers, surge protection devices, transformers, ignitors, etc. and all luminaire components, high mast luminaire carriers and raising / lowering mechanism, aiming and adjustment, lighting column / pole, supporting bracket/arm, template, fixation plate, bolts and nuts, caps, handholes, etc., concrete column/pedestal, concrete base (foundation), excavation, backfilling, shoring, formwork, blinding, insulation, reinforcement as per the structural drawings and specifications and associated cables draw-pit and other related civil works, as per the approved high mast/column detail,earthing system, as applicable, cabling inside column, obstruction lights, where specified, all relevant poles accessories and fittings. earthing system, as applicable, cost of any alteration in the column specification or foundation dimensions due to Contractor’s alternatives.