1. For the SFR problem of HW P40 Pro project, it was found that the positive field curve of the module was about 20um, In addition, there are low peak value and single line drift phenomenon. After investigation, largen lens has field curvature, H single direction field curvature is about 14um, and the normal control of lens incoming material is 7um. Through the use of p9 machine to select the lens, control the peak value of 0.85f, AA according to the value of 47 on the axis, and change the 8-line control knife edge, and the defect is reduced from 7% to 0.2%;<br>2. For the stain problem of HW P40 Pro project, when the project enters mass production, the yield is about 2.5%. According to the composition analysis, 80% is motor debris. Through the verification of AA section, the introduction of three vibration three washing and dust collecting glue, and the introduction of special tear film fixture (IR film), the overall bad stain is reduced from 2.5% to 0.7%, and the loss is about 300000 RMB per day<br>