1.4 Engineering practice<br><br>In the installation and construction of galvanized steel pipe, in view of the above-mentioned quality general disease, we must take the following countermeasures in a timely manner: (1) when cutting the metal pipe, the operator must complete the preventive measures to cross the bottom work, to ensure that the saw pipe port to remain straight, no burrs appear; (2) The thickness of the protective layer of the pipeline is at least 15mm, and the mortar strength of the wall is at least 10MPa; (3) When a non-galvanized steel pipe is connected by thread, two welding spans are required to be connected with the ground wire; When a galvanized steel condule is threaded, the connection at both ends is connected with a special ground card in order to connect with a jumper ground wire; (4) When the thickness of galvanized pipe wall is less than 2mm, welding can not be carried out with the help of casing, and the casing and screws must be matched with each other, and the electrical continuity test is completed; (5) After the pipeline is installed, it also needs to do a good job of product protection.<br><br>2 Metal pipeline protection ground installation problems and prevention and control measures<br><br>2.1 Phenomenon<br><br>The cross-section of the metal protective ground is small and can not meet the standard requirements at all. The anti-corrosion paint brush in the pipe and welding area is not perfect enough; The work of the inner concrete protective layer is not perfect.<br><br>2.2 Reason<br><br>(1) When the wires and ground wires are welded to each other, the cross-sectional relationship between the ground wire and the wires in the tube is not usually considered; (2) confusing the ground line with its importance; (3) the purpose and position of painting anti-rust paint in the metal wire pipe is not clear enough; (4) Before pouring concrete, the pipe is not cushioned with concrete prefabribriced blocks, resulting in the bottom layer protection layer work is not thorough enough.<br><br>2.3 Preventive response<br><br>(1) When the metal pipeline and ground wire are connected, the two sections shall be welded using quasi-4mm galvanized wire or quasi-6mm or more steel bars. Therefore, the ground section area welded with the trunk pipe is at least 1/2 of the cross-phase cross-sectional area of the pipe, and when it is a branch line, at least 1/3 of the cross-sectional area of the cross-sectional line. At the same time, the welding length of the ground wire should be at least 6 times the diameter of the connecting line. (2) The surface of the online tube should be coated with a layer of anti-corrosion paint. In the concrete practice construction, in addition to laying in the concrete metal pipe, other parts must be coated with a layer of anti-corrosion paint. For metal lines laid into the soil, the thickness of the pipes must be at least 3mm or more. During the pouring process, make sure that the prefabrio concrete blocks can cushion the pipe so that the thickness of the concrete protective layer around the pipe is at least 5cm.
正在翻译中..