With the button fully-depressed, the part must lift out of its attachment location with no more than 18 lbs of upwards force. Test this by holding the button down with up to 14 lbs of force, confirming that the button is depressed enough to allow part removal and it is not opposing removal of the part. While maintaining that, then apply upwards force to pull the part out of the socket and measure the upwards lifting force required.