The test current is an alternating current of the value shown in Table 11.Rewireable accessories are fitted with conductors of a cross-sectional area as specified in Table 11, the terminal screws or nuts being tightened with a torque specified on the product or in the instruction sheets by the manufacturer or equal to two-thirds of that specified in Table 19.For the purpose of this test, a length of at least 2 m of the cable is connected to the terminals.Non-rewireable accessories are tested as delivered.For accessories having three or more poles, the test current during the test shall be passed through the phase contacts. If there is a neutral contact, a separate test shall be carried out passing the test current through the neutral contact and the nearest phase contact.A further separate test shall be carried out passing the test current through the earthing contact and the nearest phase contact.A current of 2 A shall be passed through the pilot contact, if any, during any of these tests.Table 11 - Temperature rise test