Moreover the ductile behaviour of joints is guaran-teed by defining an appropriate hierarchy of strengthsfor each component. In this respect and with referenceto sagging moments, the end-plate and the column flange under bending, as well as the column web panelin shear, have to be considered ductile components,while the concrete slab under compression and the boltsunder tension are assumed to be brittle.