I am contacting you regarding Power Supply Cord PN 692003B4, we received an answer regarding the samples sent. I have asked to supplier the questions from your previous e-mail, and you can find their answer below: The twist distance of insulator recorded in the specification is Max: 90mm, while MCC is evaluating the measured twisting distance of insulator is 98mm(Average value) Please confirm whether the sample sent is wrong? It was a mistyping by the supplier, please find below the answer:“I apologize for the confusion regarding the twist distance - we usually declare the twist distance with the tolerance +/- 10% as this is standard for the production. This means that the sample you received is within the tolerance and is to be considered OK.” ※ MCC completed the bending test, the result is still NG (Power cord sheath displacement out of reference) “As for the sheathing displacement, the only way to prevent the sheathing displacement is to increase the sheathing compound hardness. However, this modification will negatively affect the cold bending test, which the cable will not pass according to your requirements, just as the current cable you are using is not passing (judging by the cable we received from you). Please make sure that your colleagues in Japan are also aware of this fact and consider it in the evaluation of our cable.” (please find attached from the past the results of supplier ) Please, analyze this matter, and let us know your opinion until 9/03/2020.