AS per API 617 Annex F, allowable nozzle loads for centrifugal compressors to be supplied by vendor with quotation. For Compressor nozzles, the nozzle load compliance check shall be limited to maximum operating temperature, seismic, wind & occasional loading (PSV etc.) conditions.