#2样品分析步骤:<br>1, check the charging case connected USB cable can be normal charging, but can not charge the headset, use the universal meter to measure the charging case charging probe no 5v output.<br>2, disassembling the charging box, measuring the charging case battery voltage of 4.0v, battery voltage is normal, the use of the meter to measure the charging case PCBA board boost IC output foot has 5v output, in the boost IC output trunk and branch of the combination point measurement found that the voltage has dropped to 3.33v, voltage anomalies, branch components leakage.<br>3, remove the line D4 bit number of the ESD tube, the charging box returned to normal, can normally charge the headset, replace the new D4 bit number of the ESD tube, the charging box is still normal.<br>4, test headset found that the right headset does not turn on, and charging when no light.<br>5, test headphone PCBA board static current is normal, battery capacity test is normal. The headset can charge properly and start-up properly after replacing the new battery. (The defective battery has been sent back to Viduli to assist in the confirmation analysis, expected to reply on December 17) (Battery capacity test see annex)