All weldment separating different environments must be realized to guarantee oil sealing. The partial joint preparation shall have a non-welded-zone useful for venting during PWHT. The nonwelded-zone shall be on external surfaces and shall be closed after PWHT. Alternatively, a 4 mm (maximum) vent hole shall be realized as shown below and it shall be closed. After PWHT