Removing the encoder mounting adapter 1. Loosen the screws [22] and remove the forced cooling fan guard [170]. 2. Remove the cable grommet [269] from the fan guard [170]. 3. Loosen the screws [232] and turn the conical spring washers [251] to the side. Loosen the screw of the coupling clamping hub [233] on the encoder end and re- move the encoder [220]. The intermediate flange [225] and screws [226] can re- main at the encoder mounting adapter [A]. 4. Loosen the screws [1458] and [936] and remove the encoder mounting adapter [A]. The torque brackets [935] and screws [1463] can remain at the encoder mounting adapter [A]. • If the encoder mounting adapter [A] cannot easily be removed: Screw in a set screw M6 with 20 – 35 mm length into the rotor bore (bore for screw [1458]) and tighten it finger-tight. Screw in a set screw M8 with > 10 mm length or a screw M8 with min. 80 mm length into the same bore and push out the encoder mounting adapter [A] from the rotor [1]. Then remove the set screw M6 from the rotor again.