The profile pulses sto stay within the minimum permitted discharge voltage) to permit the later calculation of lowtemperature cranking power capability (see Table 20). 7.6.3 Requirement The results shall be delivered as graphic representations of power versus time profiles, including current, voltage and temperature values. 7.7 Cranking power at high temperature7.7.1 Purpose The test for cranking power at high temperature is intended to measure power capabilities at a high temperature of 50 °C or the maximum temperature specified by the supplier. The aim is to generate a database of time-dependent power output at high temperatures. This test applies to high-power battery systems only. 7.7.2 Test procedure The test for cranking power at 50 °C shall be performed at the lowest SOC level permitted as specified by the supplier according to the test sequence in Table 21. Table 19 (continued)38 © ISO 2018 – All rights reserved