6.1.2. Fluid (gas or liquid) inlet connections, except individual plumbing Items (e.g., fittings and hoses) and connections completed prior to shipment, shall have identification (fluid name or formula) and maximum working pressure rating ((bar or pascal) and psi) markings (e.g., labels).6.1.3. Each Item shall be provided with documentation, in English, necessary for the safe installation and use of the Item. The information in the documentation shall include the following applicable information:6.1.3.1.A description of the intended use and general operating conditions6.1.3.2.Installation, service, and maintenance procedures that include instructions for isolation (“lockout/tagout”) of hazardous energies, recommendations for personal protective equipment, and tools or equipment required to perform each task.6.1.3.3.Operating instructions6.1.3.4.A description of hazards associated with the Item and controls to mitigate the hazards, including an explanation of auditory and visual alerts (e.g., status lights).