35.5 At the conclusion of the observation period, the DUT shall be subjected to an ″as received″ dielectric voltage withstand test in accordance with Section 18. The DUT shall be examined for signs of rupture and evidence of leakage.35.6 As a result of the salt fog test, the following in (a) – (h) are considered non-compliant results. For additional information on non-complying results refer to Table 10.1.a) E – Explosion;b) F – Fire;c) C – Combustible vapor concentrations;d) V – Toxic vapor release;e) S – Electric shock hazard (dielectric breakdown);f) L – Leakage (external to enclosure of DUT);g) R – Rupture (of DUT enclosure exposing hazardous parts as determined by 5.3.3);h) P – Loss of protection controls.