Force requirements:<br>The entire load of the Support structure is assumed by the steel beam at the top of the venue, connected by 8 ropes to the steel beam at the top of the structure, each of which is considered a reliable lifting point, as each lift point of the Support structure changes as the load moves. Therefore, take the maximum load value of each lifting point as the standard load value, consider the safety factor of 3 times, the maximum load value of the lifting point multiplied by 3 as the support structure acting on the design load value of the steel beam at the top of the structure. In this engineering design, the design load value of each ceiling point of the support structure acting on the steel beam at the top of the structure is 15kN (see calculation book for details). In addition, the top steel beams of the venue should consider overlaying all external loads for overall review