The Negative Cleaning Roller Bias means the voltage supplied to the Cleaning Roller during the Toner Collection Process, which is done after the completion of Print Process. The standard value of the Negative Cleaning Roller Bias is -500 +/-5V. Check and adjust it in the following way.