This section applies to slender-element compression members, as defined in Section B4.1 for elements in axial compression.The nominal compressive strength, Pn, shall be the lowest value based on the appli- cable limit states of flexural buckling, torsional buckling, and flexural-torsional buckling in interaction with local buckling.