Figure 3 shows the in-plane axial stress sx in the transfer plates of both the complete and simplified models. It is seen that although two structures are subjected to the same loading, the in-plane axial forces of the transfer plate in the complete model are smaller that those in the simplified one. This is obviously caused by the effect of interaction between the transfer plate and shear wall in the complete