Connections shall be made using the production approved connection system, including connector body,terminal, seals, crimp, Terminal Position Assurance (TPA), Connector Position Assurance (CPA), listed on the part drawing. Deviation from this requirement shall require the appropriate responsible GM Engineer approval.Application test circuits used for performance and durability testing shall use the appropriate application specific wire gage and length. The actual in vehicle length or maximum of 3 m should be used if possible.Table 5 depicts recommended wire gage selection as a function of test load for use when application specific wire gage information is not available.