FM1: The contribution rate is 45%, which shows that the ink is damaged and stained with gold, and there is no scratch mark. The section shows that the damaged opening has undercut, and it is judged that the hole is stained with gold due to exposure of foreign bodies.<BR><BR>FM2: contribution rate: 20%. Slice confirmed that the damaged ink had protrusions, and it was judged that it was caused by foreign bodies falling off in the ink.<BR><BR>FM3: The contribution rate is 15%, and there are traces of white ink around the damage, and there are no scratches. Slicing confirms that there is still ink residue on the copper surface, and there is no nickel layer and gold layer; The analysis shows that the ink foreign body falls off without causing copper leakage.<BR><BR>FM4: the contribution rate is 15%, and it is abnormal in the form of a lump of foreign matter protruding, with no fixed position (pcs), which can be seen visually. It is analyzed that it is caused by ink foreign matter.<BR><BR>FM5: the contribution rate is 5%, and the analysis of foreign bodies is caused by scratches and holes after printing ink.