(3) Aerated tank. The aeration tank is the main degradation site of pollutants in water, and the proliferation of microorganisms is realized. The aeration tank uses a combination of centrifugal blowers and microporous aerators to provide sufficient oxygen sources for the biochemical degradation of organic matter in this area and the removal of BOD5 and CODCr from the water. The on-line dissolved oxygen meter is set up at the end of the aeration tank to monitor dissolved oxygen in the mixture in real time and control the mass concentration of the outlet dissolved oxygen at about 2.0mg/L. In order to prevent the hair and other fibrous substances in sewage from entering the follow-up membrane bioreactive membrane pool, set up 2mm × 2mm stainless steel grid on the aeration tank outlet channel, and the sewage flows through the grid and then flows into the membrane bioreactive membrane pool.<br>(4) Membrane bioreactive membrane pool. Membrane bioreactive membrane pool is installed with membrane components, through membrane filtration to achieve mud water separation, activated sludge is intercepted outside the membrane, membrane water through membrane bioreactive water production pump to the outer drainage or reuse of the pool.<br>(5) Sludge pool. The end of the membrane bioreactive membrane pool is equipped with a sludge pool, and the sludge reflux pump is set up to return the membrane pool mixture to the distribution well, and the maximum reflux ratio is designed to be 150%, and the sludge mass concentration of the membrane bioreactive membrane pool is controlled at least 3000mg/L. The remaining sludge is discharged into the remaining sludge well according to the operation of the process.