分别取供试品约1.3g(仪器推荐进样重量)、2g、3g,精密称定,置仪器配套量筒中,使供试品淹没过量筒底部圆弧部分,将量筒放于干法测试模块(的英语翻译

分别取供试品约1.3g(仪器推荐进样重量)、2g、3g,精密称定,置仪

分别取供试品约1.3g(仪器推荐进样重量)、2g、3g,精密称定,置仪器配套量筒中,使供试品淹没过量筒底部圆弧部分,将量筒放于干法测试模块(DPS)中。软件加载对应的检测方法,仪器运行“偏移”、“排列”、“背景”程序后,开始分析,导出测试结果,收集D10、D50、D90数据。每个重量平行测试3份。在称样量为1.3g、2g、3g条件下测定的结果RSD分别为1.4%、1.2%、2.2%,且结果均符合标准要求,供试品称样量对检测结果无明显影响,因此选择仪器推荐重量1.3g作为测定条件。9.1.2真空度取供试品约1.3g,精密称定,置仪器配套量筒中,使供试品没过量筒底部圆弧部分,将量筒放于干法测试模块(DPS)中。分别在真空度为15 " H2O、20 " H2O、30 " H2O(仪器最大真空度)条件下进行测定,收集D10、D50、D90数据。每个真空度平行测试3份。方法参数:测量漂移:测量背景:折射率:在真空度为15 " H2O、20 " H2O、30 " H2O条件下测定结果,其D10、D50、D90的RSD分别为2.0%、3.1%、3.0%,说明真空度对检测结果无明显影响,真空度在15 " H2O~30 " H2O均适用于微晶纤维素粒度分布检测。真空度30 " H2O为仪器最大真空度和默认真空度,为使样品获得最优分散效果,且防止真空度掉落至15 " H2O以下,选取仪器最大真空度30 " H2O作为测定条件。
0/5000
源语言: -
目标语言: -
结果 (英语) 1: [复制]
复制成功!
Were taken about 1.3 g of the test (Instrument Recommended sample weight), 2g, 3g, accurately weighed, placed in the instrument support cylinder, so that the test cylinder bottom through the submerged arc portion, the cylinder is placed in a dry test module (DPS) in. <br>The method of loading the software corresponding to the detection, operation of the instruments "offset", "arrangement", the "background" program, start the analysis, test results derived collected D10, D50, D90 data. <br>3 parts by weight of each parallel test. <br>In the sample weight was 1.3g, 2g, 3g measured under conditions were the results of RSD 1.4%, 1.2%, 2.2%, and the results are in line with the requirements, the test sample weight had no effect on the detection results, thus selected recommended by weight of 1.3g as the measurement instrument conditions. <br>9.1.2 degree of vacuum <br>of the test sample of about 1.3g, accurately weighed, placed in the instrument support cylinder, so too did the test cylinder bottom arc portion, the cylinder is placed in a dry test module (DPS) in. <br>Respectively 15 "H2O, 20" H2O, 30 " carried out in H2O (instrument maximum vacuum) measurement conditions, collecting D10, D50, D90 vacuum degree of data <br>each parallel testing the degree of vacuum of 3 parts <br>: Method Parameter <br>Measurement drift: <br>bACKGROUND measurement: <br>refractive index: <br>15 "H2O, 20 is" H2O, measured 30 "H2O under conditions result which D10, D50, D90, respectively, the RSD of 2.0%, 3.1%, 3.0%, indicating the degree of vacuum of the vacuum degree of the detection results no significant effect on the degree of vacuum in 15 "H2O ~ 30" H2O are applicable to detect the particle size distribution of microcrystalline cellulose. <br>The degree of vacuum 30 "H2O and the instrument default maximum vacuum degree of vacuum, in order to obtain an optimal dispersion effect of the sample, and preventing the degree of vacuum falls to 15" H2O or less, the maximum vacuum level select instrument 30 "H2O measurement conditions.
正在翻译中..
结果 (英语) 2:[复制]
复制成功!
Take the test product about 1.3g (the recommended sample weight of the instrument), 2g, 3g, precision, set the instrument supporting the cylinder, so that the test product drowns the arc part of the bottom of the excess cylinder, put the measuring barrel in the dry test module (DPS).<br>The software loads the corresponding detection method, the instrument runs the "offset", "arrangement", "background" program, begins to analyze, export the test results, collect D10, D50, D90 data.<br>3 parallel tests for each weight.<br>The results of RSD measured under the weighing volume of 1.3g, 2g and 3g were 1.4%, 1.2% and 2.2% respectively, and the results all met the standard requirements, and the sample weighing for the test product had no obvious effect on the test results, so the recommended weight of 1.3g was selected as the determination condition.<br>9.1.2 Vacuum<br>Take the test product about 1.3g, precision, set the instrument supporting the cylinder, so that the test product does not excessive barrel bottom arc part, the measuring tube placed in the dry test module (DPS).<br>The D10, D50, D90 data are collected, and D10, D50, and D90 data are collected, respectively, under the conditions of vacuum of 15 " H2O, 20 " H2O, and 30 " H2O (maximum vacuum degree of the instrument).<br>3 in parallel for each vacuum degree.<br>Method parameters:<br>Measuring drift:<br>Measurement background:<br>Refractive index:<br>The results of the rsD of D10, D50 and D90 were 2.0%, 3.1%, and 3.0% respectively under the condition of vacuum of 15 x H2O, 20 x H2O, 30 , H2O, h2O, H2O, H2O, and D90, respectively, indicating that the vacuum degree had no obvious effect on the test results, and the vacuum degree was 15 "H2O to 30" H2O is suitable for microcrystalline cellulose particle size distribution detection.<br>Vacuum degree 30, H2O is the maximum vacuum and default vacuum degree of the instrument, in order to obtain the optimal dispersion effect of the sample, and prevent the vacuum degree from falling below 15 s" H2O, select the maximum vacuum degree of the instrument 30" H2O as the determination condition.
正在翻译中..
结果 (英语) 3:[复制]
复制成功!
Take about 1.3g (recommended injection weight of the instrument), 2G and 3G of the test sample respectively, weigh accurately, and place them in the measuring cylinder matched with the instrument, so that the test sample can submerge the arc part at the bottom of the excessive cylinder, and place the measuring cylinder in the DPS.<br>The software loads the corresponding detection methods. After the instrument runs the "offset", "arrangement" and "background" programs, it starts to analyze, export the test results, and collect D10, D50 and D90 data.<br>3 parallel tests for each weight.<br>The RSD of the test results were 1.4%, 1.2% and 2.2% respectively under the conditions of weighing 1.3g, 2G and 3G, and the results met the requirements of the standard. The weighing of the test sample had no obvious influence on the test results, so the instrument recommended 1.3g as the test condition.<br>9.1.2 vacuum degree<br>Take about 1.3g of the test sample, weigh accurately, and place it in the measuring cylinder matched with the instrument, so that the test sample does not exceed the arc part at the bottom of the cylinder, and place the measuring cylinder in the DPS.<br>Measure under the conditions of 15 "H2O, 20" H2O and 30 "H2O (maximum vacuum of the instrument), and collect D10, D50 and D90 data.<br>3 parallel tests for each vacuum degree.<br>Method parameters:<br>Measurement drift:<br>Measurement background:<br>Refractive index:<br>The RSD of d10, D50 and D90 were 2.0%, 3.1% and 3.0% respectively under the conditions of 15 "H2O, 20" H2O and 30 "H2O, which indicated that the vacuum had no obvious influence on the test results. The vacuum degree of 15" H2O ~ 30 "H2O was suitable for the particle size distribution test of microcrystalline cellulose.<br>The vacuum degree of 30 "H2O is the maximum vacuum degree and default vacuum degree of the instrument. In order to obtain the best dispersion effect of the sample and prevent the vacuum degree from falling below 15" H2O, the maximum vacuum degree of 30 "H2O of the instrument is selected as the determination condition.<br>
正在翻译中..
 
其它语言
本翻译工具支持: 世界语, 丹麦语, 乌克兰语, 乌兹别克语, 乌尔都语, 亚美尼亚语, 伊博语, 俄语, 保加利亚语, 信德语, 修纳语, 僧伽罗语, 克林贡语, 克罗地亚语, 冰岛语, 加利西亚语, 加泰罗尼亚语, 匈牙利语, 南非祖鲁语, 南非科萨语, 卡纳达语, 卢旺达语, 卢森堡语, 印地语, 印尼巽他语, 印尼爪哇语, 印尼语, 古吉拉特语, 吉尔吉斯语, 哈萨克语, 土库曼语, 土耳其语, 塔吉克语, 塞尔维亚语, 塞索托语, 夏威夷语, 奥利亚语, 威尔士语, 孟加拉语, 宿务语, 尼泊尔语, 巴斯克语, 布尔语(南非荷兰语), 希伯来语, 希腊语, 库尔德语, 弗里西语, 德语, 意大利语, 意第绪语, 拉丁语, 拉脱维亚语, 挪威语, 捷克语, 斯洛伐克语, 斯洛文尼亚语, 斯瓦希里语, 旁遮普语, 日语, 普什图语, 格鲁吉亚语, 毛利语, 法语, 波兰语, 波斯尼亚语, 波斯语, 泰卢固语, 泰米尔语, 泰语, 海地克里奥尔语, 爱尔兰语, 爱沙尼亚语, 瑞典语, 白俄罗斯语, 科西嘉语, 立陶宛语, 简体中文, 索马里语, 繁体中文, 约鲁巴语, 维吾尔语, 缅甸语, 罗马尼亚语, 老挝语, 自动识别, 芬兰语, 苏格兰盖尔语, 苗语, 英语, 荷兰语, 菲律宾语, 萨摩亚语, 葡萄牙语, 蒙古语, 西班牙语, 豪萨语, 越南语, 阿塞拜疆语, 阿姆哈拉语, 阿尔巴尼亚语, 阿拉伯语, 鞑靼语, 韩语, 马其顿语, 马尔加什语, 马拉地语, 马拉雅拉姆语, 马来语, 马耳他语, 高棉语, 齐切瓦语, 等语言的翻译.