RESERVOIR FILLINGSet the yellow electric pump to ON to make sure that the brakeaccumulator is pressurized, then set the pump to OFF.Connect the selected servicing source to the green servicing panel.When you use the panel hand pump, connect the hose to the handpump and insert it into the fluid container, and then install the pumphandle. The handle is stowed at the yellow servicing panel.When you use the external pump, connect the lower filling port andset the minimum flow (it must not be more than 435 psi).Then select the reservoir to be filled, make sure that its related lightis ON, and fill the reservoir with fluid to the upper end of the scale.NOTE: If the reservoir is filled too much, this will cause an incorrectpressurization.Large changes in ambient temperature can also have an effect on thereservoir level. For every 10°C change, the green and yellow volumeschange by 0.50 l and the blue volume changes by 0.25 l.