2.3.23 Pry resistance-2 1) Test The male and female connectors shall be fitted. Securing the male connector, pull the female connector wire at an angle of 45 to the direction to minimize the male and female terminal contact at a speed of 5mm/min. to 100N. Then, decrease the pulling load at a speed of 5 mm / min to “0” N (no load). Specify the pulling load waveform during these actions.2) Performance The inclination of the loading waveform shall be uninterrupted while increasing and decreasing the load. (Fig.2.3.11 provides an example of interrupted waveform.)