A stability analysis shall be performed on all centrifugal compressors, steam turbines and axial and/or radial flow rotors except those rotors whose maximum continuous speed is below the first critical speed in accor-dance with SP6.8.2.3 as calculated on rigid supports. For this analysis, the machine inlet and discharge conditions shall be at the rated condition unless the vendor and pur-chaser mutually agree upon another operating point.