B2.2 MechanicalB2.2.1 Cell shock testB2.2.1.1 A fresh sample of cell or fully charged small battery module (per MOSOC of 6.1) shall comply with the shock test as outlined below.B2.2.1.2 The sample is to be secured to the testing machine by means of a rigid mount, which supports all mounting surfaces of the sample. Each sample is to be subjected to a total of three shocks of equal magnitude. The shocks are to be applied in each of three mutually perpendicular directions for a total of 18 shocks unless the sample has only two axes of symmetry, in which case only two directions are tested for a total of 9. The parameters of the shock applied are as noted in the Table B.2 below. The shocks shall be applied with the sample at room temperature of 25 ±5°C. At the conclusion of the shock testing the sample is operated (i.e. charged/discharged) at its normal operating temperature for 1 cycle to determine if is has been made hazardous as a result of the shock conditioning