(Crimp joints larger than 10 mm² have to use the CFM-system where it makes sense). If Faulty Crimps or Missing Wires are detected or Crimping on Insulation is detected). If Integrated Cut-Modules are not fitted or able to cut the Crimped Terminals with failures Off (IE. Due to Wire Size), the plant QM has to implement An Action Plan, “System to Detect and Destroy” Failed Crimped Leads Safely (For example by a Predetermined Action Plan, with Effective Operator – Staff Training). CFM Controlled Cut-Modules are Mandatory & Can Only be Replaced with an Effective Manual System or Process Under a Controlled Deviation). Example: During production if in 10 consecutive crimped leads the CFM signals more than 3 failed crimps (and the failure mode is not identifiable), stop work and inform the QM and TS department for Detailed Investigation.