8.6.2.4 Where an 8 mm cutoff is required to measure a surface texture and the available measuring instrument has a maximum cutoff of 2.5 mm, the surface may be measured using the2.5 mm cutoff and the Ra reading multiplied by the appropriate factor from Figure 8 to calculate a Ra value equivalent to measuring the surface using a 8 mm cutoff.