Caution!Only trained and qualified personnel should made the necessary changes. To change one of these values, you have to point to the data field andthen you may type the new value directly by the numerical keypad.Speed controlIn this downstream drives menu there are the data fields to control thecalender and the haul-off drives. You may enter the setpoint value forthe speed of the roll drives and the haul-off drive here. The set valuefor roll 2 (line speed, master drive) is entered in meters per minute,while the values for the other drives are entered as ratio (0.800 to1.200) relative to the speed of roll 2.Actual speed values and current consumption (load) of the drives arealso displayed in this calender menu.Note!If the factor (ratio) is less than 1, the concerned slave drive runs slowerthan the master drive. A factor equal to 1 means, that the concerned driveruns exactly with the same speed as the master drive. If the factor is greater than 1, the concerned drive runs faster than the master drive.Note!You may control the haul off drive by adjusting the speed set value(correction factor) or via the tension control. In the tension control modethe setpoint for the drive is entered in N (film tension force).