Because the QXD series oil heater cycle pipe use time is too long, resulting in pipe wear, loopholes, and ultimately lead to QXD series oil heater cycle pipe leakage. <br><br>1. When oil spills, the cyclophosphamide chlorination reaction is using the equipment for temperature control, taking into account the high temperature of the thermal oil in the pipeline and a certain amount of pressure, so temporarily stop the operation of the QXD series oil heater, after the repair man temporarily bandaged the oil leak pipe, restart the system to ensure that the R1502 tank can maintain the required reaction temperature, and during the pipe packing, the temperature record from normal operation (30 to 5 minutes) recorded to 10 minutes, The temperature recorded per (30-5) minutes is restored until the system is operational, ensuring that the temperature in the R1502 can is validly recorded during the system's shutdown. The pipe is bandaged for 30 minutes and its temperature has been dropping, with a minimum of 93.5 degrees C, which does not exceed the temperature control requirement (92 degrees C-98 degrees C). The reaction start time is 12:10, the end time is 15:10, the total reaction time is 3 hours, and the reaction time is met (reaction 3 hours). Therefore, there is no impact on the quality of the product.<br>2. Tracking detection of cyclophosphamide, quality in line with the requirements, risk control.<br>3. After the pipeline oil leakage is found, other pipelines are checked, and no oil leakage from other pipes.<br><br>1. Repair the leaking lines.<br>2. Check all pipes of the QXD series oil heater, repair or replace the faulty pipe.