Product from the reaction section is vacuum distilled in the Dehydration Column (C3100) to remove MeSH, water, and residual acetone. The feed to the Dehydration Column is partially heated first in the Guard Bed Inlet Heater (E3005), using low pressure (S4) steam. This heating is done prior to the Guard Bed (D3005) and is shown in drawing 106-0002.