From Fig. 2, it can be seen clearly that for different blade number, the static pressure gradually increase from impeller inlet to outlet, the static pressure on pressure side is evidently larger than that on suction side at the same impeller radius. With the increase of blade number, the static pressure at volute outlet grows all the time, and the uniformity of static pressure distributions at screw section become worse and worse, but at diffusion section become better and better.