14.2.2 Test for second characteristic numeral 2 with the drip box The dripping device is the same as specified in 14.2.1 adjusted to provide the water flow rate specified in table 8. The table on which the enclosure is placed does not turn as in the case of the test for the second characteristic numeral 1. The enclosure is tested for 2,5 min in each of four fixed positions of tilt. These positions are 15° on either side of the vertical in two mutually perpendicular planes (see figure 3b)). The total duration of the test is 10 min