接下来我将介绍pH计的使用。首先我先介绍一下pH计,pH计操作面板上的按钮有:pH/mV模式切换按钮、温度、斜率、定位调节按钮及确认按钮,还有一只复合电极。准备工作:接下来开始使用pH计,取出电极保护套,pH复合电极连接到pH计,连接pH计电源线,将pH计预热五分钟以上。按pH/mV按钮,切换到pH模式,此时仪器屏幕右上角显示pH,按温度按钮,再按确认,按上下键将温度调至实验室环境温度,确认。取出适量pH计校准液于烧杯中,蒸馏水冲洗电极,用滤纸擦干电极。使用pH为6.86的校准液冲洗电极,吸干电极上的液体,打开电极后部的橡胶塞,将电极置于pH为6.86的校准液中,进行定位,轻轻摇动烧杯,按定位按钮再按确认,按上下键调节pH至6.86,最后按确认按钮,定位完毕。用蒸馏水冲洗电极并用吸水纸擦干,使用pH为4.00的校准液冲洗电极,吸干电极上的液体,将电极置于pH为4.00的校准液中,调节斜率,轻轻摇动,按上下键调节pH至4.00,最后确认按钮。校准完毕,可用来测酸性溶液的pH值。测定溶液的pH值,先用蒸馏水冲洗电极,用滤纸擦干,再用被测液清洗一次,吸干电极上的液体,用玻璃棒搅拌溶液,使溶液均匀,把电极浸入被测溶液中,轻摇烧杯,待数字稳定后读取,读出其pH值,平行测量三次,记录数据。测试完毕,清洗电极,用滤纸吸干,套上复合电极保护套,套内应放少量补充液(电极保护液),关掉电源,拔下电极线,拔掉电源线,摆好仪器,收拾好桌面。pH计的使用介绍完毕,谢谢聆听。
0/5000
源语言: -
目标语言: -
结果 (英语) 1: [复制]
复制成功!
Next, I will introduce the use of pH meters. First, let me introduce the pH meter. The buttons on the pH meter operation panel include: pH/mV mode switching button, temperature, slope, positioning adjustment button and confirmation button, and a composite electrode. Preparation: Next, start using the pH meter, take out the electrode protective cover, connect the pH composite electrode to the pH meter, connect the power cord of the pH meter, and preheat the pH meter for more than five minutes. Press the pH/mV button to switch to pH mode. At this time, pH is displayed in the upper right corner of the instrument screen. Press the temperature button, and then press OK. Press the up and down keys to adjust the temperature to the laboratory environment temperature and confirm. Take out an appropriate amount of pH meter calibration solution in a beaker, rinse the electrode with distilled water, and dry the electrode with filter paper. Rinse the electrode with a calibration solution of pH 6.86, suck up the liquid on the electrode, open the rubber plug on the back of the electrode, place the electrode in the calibration solution of pH 6.86 for positioning, gently shake the beaker, press the positioning button and then press To confirm, press the up and down keys to adjust the pH to 6.86, and finally press the confirm button to complete the positioning. Rinse the electrode with distilled water and dry it with absorbent paper, rinse the electrode with pH 4.00 calibration solution, absorb the liquid on the electrode, place the electrode in the pH 4.00 calibration solution, adjust the slope, shake it gently, and press the up and down keys to adjust pH to 4.00, finally confirm button. After calibration, it can be used to measure the pH value of acidic solution. To determine the pH value of the solution, first rinse the electrode with distilled water, wipe it dry with filter paper, and then clean it with the test solution once, soak up the liquid on the electrode, stir the solution with a glass rod to make the solution uniform, and immerse the electrode in the test solution. Shake the beaker gently, read it after the number is stable, read the pH value, measure three times in parallel, and record the data. After the test, clean the electrode, dry it with filter paper, put on the composite electrode protective cover, put a small amount of replenisher (electrode protective liquid) in the cover, turn off the power, unplug the electrode cord, unplug the power cord, set up the instrument, and tidy the desktop . The introduction to the use of the pH meter is complete, thank you for listening.
正在翻译中..
结果 (英语) 2:[复制]
复制成功!
Next I'll cover the use of pH meters. First of all, I would like to introduce the pH meter, pH meter operator panel buttons are: pH/mV mode toggle button, temperature, slope, positioning adjustment button and confirmation button, and a composite electrode. Preparation: Next, start using the pH meter, remove the electrode protection case, pH composite electrode connected to the pH meter, connect the pH meter power cord, the pH meter preheat more than five minutes. Press the pH/mV button, switch to pH mode, at this time the upper right corner of the instrument screen shows pH, press the temperature button, then press the confirmation, press the upper and lower keys to adjust the temperature to the laboratory ambient temperature, confirm. Remove the appropriate amount of pH meter calibration fluid in the beech, rinse the electrode with distilled water, and dry the electrode with filter paper. Rinse the electrode with pH 6.86 calibration fluid, absorb the liquid on the electrode, open the rubber plug at the rear of the electrode, place the electrode in the pH 6.86 calibration fluid, position it, gently shake the beo cup, press the positioning button and press the confirmation, press the upper and lower keys to adjust the pH to 6.86, and finally press the confirmation button to position it. Rinse the electrode with distilled water and dry it with absorbent paper, rinse the electrode with pH 4.00 calibration fluid, absorb the liquid on the electrode, place the electrode in the pH 4.00 calibration fluid, adjust the slope, shake gently, press the upper and lower keys to adjust pH to 4.00, and finally confirm the button. The calibration is complete and can be used to measure the pH of the acidic solution. To determine the pH of the solution, first rinse the electrode with distilled water, dry it with filter paper, clean it once with the measured liquid, absorb the liquid on the electrode, stir the solution with a glass rod, make the solution even, dip the electrode into the solution under test, shake the beo cup lightly, read it after the number stabilizes, read its pH, measure it three times in parallel, record the data. After testing, clean the electrode, vacuum dry with filter paper, set up a composite electrode protection case, the set should put a small amount of rehydration liquid (electrode protection fluid), turn off the power supply, unplug the electrode wire, unplug the power cord, set up the instrument, clean up the table. The introduction to the use of the pH meter is complete, thank you for listening.
正在翻译中..
结果 (英语) 3:[复制]
复制成功!
Next, I will introduce the use of pH meters. First of all, I will introduce the pH meter. The buttons on the pH meter operation panel include: pH / MV mode switch button, temperature, slope, positioning adjustment button and confirmation button, as well as a composite electrode. Preparation: next, start to use the pH meter, take out the electrode protective sleeve, connect the pH composite electrode to the pH meter, connect the pH meter power line, and preheat the pH meter for more than five minutes. Press the pH / MV button to switch to pH mode. At this time, pH is displayed in the upper right corner of the instrument screen. Press the temperature button, and then press confirm. Press the up and down keys to adjust the temperature to the ambient temperature of the laboratory. Confirm. Take out an appropriate amount of pH meter calibration solution in the beaker, wash the electrode with distilled water, and dry the electrode with filter paper. Rinse the electrode with the calibration solution of pH 6.86, absorb the liquid on the electrode, open the rubber plug at the back of the electrode, place the electrode in the pH 6.86 calibration solution, position it, gently shake the beaker, press the positioning button, then press the confirmation button, press the up and down keys to adjust the pH to 6.86, and finally press the confirm button to complete the positioning. Wash the electrode with distilled water and wipe it dry with absorbent paper, rinse the electrode with pH 4.00 calibration solution, absorb the liquid on the electrode, place the electrode in the calibration solution with pH 4.00, adjust the slope, gently shake, press the up and down keys to adjust the pH to 4.00, and finally confirm the button. After calibration, it can be used to measure the pH value of acid solution. To determine the pH value of the solution, first wash the electrode with distilled water, dry it with filter paper, and then clean it once again. Absorb the liquid on the electrode, stir the solution with a glass rod to make the solution uniform, immerse the electrode into the solution to be measured, shake the beaker gently, read out the pH value after the number is stable, measure it three times in parallel, and record the data. After the test, clean the electrode, dry it with filter paper, put on the composite electrode protective sleeve, put a small amount of supplementary solution (electrode protection liquid) in the sleeve, turn off the power supply, pull out the electrode wire, pull out the power line, set up the instrument and clean up the table top. The introduction of pH meter is finished. Thank you for listening.<br>
正在翻译中..
 
其它语言
本翻译工具支持: 世界语, 丹麦语, 乌克兰语, 乌兹别克语, 乌尔都语, 亚美尼亚语, 伊博语, 俄语, 保加利亚语, 信德语, 修纳语, 僧伽罗语, 克林贡语, 克罗地亚语, 冰岛语, 加利西亚语, 加泰罗尼亚语, 匈牙利语, 南非祖鲁语, 南非科萨语, 卡纳达语, 卢旺达语, 卢森堡语, 印地语, 印尼巽他语, 印尼爪哇语, 印尼语, 古吉拉特语, 吉尔吉斯语, 哈萨克语, 土库曼语, 土耳其语, 塔吉克语, 塞尔维亚语, 塞索托语, 夏威夷语, 奥利亚语, 威尔士语, 孟加拉语, 宿务语, 尼泊尔语, 巴斯克语, 布尔语(南非荷兰语), 希伯来语, 希腊语, 库尔德语, 弗里西语, 德语, 意大利语, 意第绪语, 拉丁语, 拉脱维亚语, 挪威语, 捷克语, 斯洛伐克语, 斯洛文尼亚语, 斯瓦希里语, 旁遮普语, 日语, 普什图语, 格鲁吉亚语, 毛利语, 法语, 波兰语, 波斯尼亚语, 波斯语, 泰卢固语, 泰米尔语, 泰语, 海地克里奥尔语, 爱尔兰语, 爱沙尼亚语, 瑞典语, 白俄罗斯语, 科西嘉语, 立陶宛语, 简体中文, 索马里语, 繁体中文, 约鲁巴语, 维吾尔语, 缅甸语, 罗马尼亚语, 老挝语, 自动识别, 芬兰语, 苏格兰盖尔语, 苗语, 英语, 荷兰语, 菲律宾语, 萨摩亚语, 葡萄牙语, 蒙古语, 西班牙语, 豪萨语, 越南语, 阿塞拜疆语, 阿姆哈拉语, 阿尔巴尼亚语, 阿拉伯语, 鞑靼语, 韩语, 马其顿语, 马尔加什语, 马拉地语, 马拉雅拉姆语, 马来语, 马耳他语, 高棉语, 齐切瓦语, 等语言的翻译.

Copyright ©2024 I Love Translation. All reserved.

E-mail: