Components must be rotated and inspected at a distance of 45-60 cm (18-24 inches) or arm’s length for approximately 5 seconds per viewing side. If no defect is observed at the viewing distance, the component should be considered acceptable without searching for a reason to reject. If a defect is identified at this viewing distance, it is then permissible to pull the component closer for further inspection.