The component shall always be designed to not use more current than necessary in every mode,in a parked vehicle as well as in driving mode.To achieve above requirement the response time for customer activated functions must be withinthe required time decided by function owner and the department for Human Machine Interface.Note: Waiting for the customer to push a button is not regarded as a function that allows currentconsumption.The startup time for the continous and power supplied nodes is specified in [9] AUTOSARNetwork Management- Additional Requirements.