The membrane hydration model calculates the water content in the membrane and mass flow rate of water across the membrane. Both water content and mass flow are assumed to be uniform over the surface area of the membrane. The membrane water content and the rate of mass flow across the membrane are the functions of the stack current and relative humidity of the flow inside the anode and the cathode flow channel