The mortar of different types and strength classes in each batch of qualified blocks of not more than 250 m³ must be sampled at the exit of the mixer for at least one inspection and sampling. A set of samples should be made by sampling from the same ladle. The mortar test specimen must be manufactured in accordance with the current industry standard JGJ70 “Basic Performance Test Method of Construction Mortar”.