现在已经查明有1000个错误参数的MCU被用到这两批货中现在可以确定芯片没有问题,问题是:单片机的时钟参数有误,因为当时其中一台烧录机因故障的英语翻译

现在已经查明有1000个错误参数的MCU被用到这两批货中现在可以确定芯

现在已经查明有1000个错误参数的MCU被用到这两批货中现在可以确定芯片没有问题,问题是:单片机的时钟参数有误,因为当时其中一台烧录机因故障需要重新输入软体和时钟参数,技术员可能在某次设置中忘了改默认时钟频率参数,导致该批单片机的运行时钟比预期快1倍,从而8小时定时变成了4小时,并且没能被检验出来。这次事故影响9.02船期和9.21批次,有问题的管子共计可能有800个左右。后面订单没有受影响。一部分数量的单片机的时钟参数有误
0/5000
源语言: -
目标语言: -
结果 (英语) 1: [复制]
复制成功!
It has been found that the MCU with 1000 wrong parameters was used in these two batches. <br><br>Now it can be determined that there is no problem with the chip. The problem is: the clock parameter of the single-chip microcomputer is wrong, because at that time one of the burners needed to re-input the software due to failure In addition to the clock parameters, the technician may have forgotten to change the default clock frequency parameters in a certain setting, which caused the operating clock of this batch of single-chip microcomputers to be twice as fast as expected, so that the 8-hour timing became 4 hours, and it could not be verified. The accident affected the 9.02 shipping schedule and 9.21 batches. There may be about 800 problematic tubes in total. The subsequent orders are not affected. <br><br>The clock parameters of some microcontrollers are incorrect
正在翻译中..
结果 (英语) 2:[复制]
复制成功!
MCUs with 1,000 error parameters have now been identified as being used in both shipments<br><br>Now you can determine that the chip is no problem, the problem is: the clock parameters of the microcontrol is wrong, because one of the burners due to failure needs to re-enter the software and clock parameters, the technician may have forgotten to change the default clock frequency parameters in a certain setting, resulting in the batch of microcontrol clock than expected, so that 8 hours of timed into 4 hours, and could not be tested out. The accident affected 9.02 ships and 9.21 batches, and the total number of pipes in question could be about 800. Those following orders are not affected.<br><br>Some of the number of syn clock parameters are incorrect
正在翻译中..
结果 (英语) 3:[复制]
复制成功!
Now it has been found that the MCU with 1000 wrong parameters has been used in these two batches<br>Now it can be determined that there is no problem with the chip. The problem is: the clock parameters of the single-chip microcomputer are wrong, because one of the burners needs to re-enter the software and clock parameters due to a fault. The technician may forget to change the default clock frequency parameter in a certain setting. As a result, the operating clock of the batch of single-chip computers is twice as fast as expected, so that the 8-hour timing becomes 4-hour, and can not be checked Check it out. The accident affected the 9.02 shipping date and 9.21 batches, and there may be about 800 defective pipes. Subsequent orders have not been affected.<br>The clock parameters of some single chip microcomputers are wrong
正在翻译中..
 
其它语言
本翻译工具支持: 世界语, 丹麦语, 乌克兰语, 乌兹别克语, 乌尔都语, 亚美尼亚语, 伊博语, 俄语, 保加利亚语, 信德语, 修纳语, 僧伽罗语, 克林贡语, 克罗地亚语, 冰岛语, 加利西亚语, 加泰罗尼亚语, 匈牙利语, 南非祖鲁语, 南非科萨语, 卡纳达语, 卢旺达语, 卢森堡语, 印地语, 印尼巽他语, 印尼爪哇语, 印尼语, 古吉拉特语, 吉尔吉斯语, 哈萨克语, 土库曼语, 土耳其语, 塔吉克语, 塞尔维亚语, 塞索托语, 夏威夷语, 奥利亚语, 威尔士语, 孟加拉语, 宿务语, 尼泊尔语, 巴斯克语, 布尔语(南非荷兰语), 希伯来语, 希腊语, 库尔德语, 弗里西语, 德语, 意大利语, 意第绪语, 拉丁语, 拉脱维亚语, 挪威语, 捷克语, 斯洛伐克语, 斯洛文尼亚语, 斯瓦希里语, 旁遮普语, 日语, 普什图语, 格鲁吉亚语, 毛利语, 法语, 波兰语, 波斯尼亚语, 波斯语, 泰卢固语, 泰米尔语, 泰语, 海地克里奥尔语, 爱尔兰语, 爱沙尼亚语, 瑞典语, 白俄罗斯语, 科西嘉语, 立陶宛语, 简体中文, 索马里语, 繁体中文, 约鲁巴语, 维吾尔语, 缅甸语, 罗马尼亚语, 老挝语, 自动识别, 芬兰语, 苏格兰盖尔语, 苗语, 英语, 荷兰语, 菲律宾语, 萨摩亚语, 葡萄牙语, 蒙古语, 西班牙语, 豪萨语, 越南语, 阿塞拜疆语, 阿姆哈拉语, 阿尔巴尼亚语, 阿拉伯语, 鞑靼语, 韩语, 马其顿语, 马尔加什语, 马拉地语, 马拉雅拉姆语, 马来语, 马耳他语, 高棉语, 齐切瓦语, 等语言的翻译.