According to the vibration assessment criteria, the vibration value is below 0.71 is excellent, within 1.8 is acceptable, and the vibration can be summed up as acceptable (partial exceedings are related to vibration of other processing equipment in the field)<br>, motor temperature rise<br>According to the YE3 motor F-class insulation grade, the maximum temperature of the motor winding is 80K, allowing the maximum temperature to be no more than 155 degrees, but the maximum bearing temperature is not allowed to exceed 95 degrees, so set the maximum temperature to 70 degrees, from the above icon, the temperature rise is normal.<br>, the temperature of the case<br>Referring to CGMA 1001.D01-2007 standard worm worm deceleration oil pool temperature can not exceed 95 degrees, the gearbox adapts to the ambient temperature of -20-45 between the operation, set the maximum temperature rise of the box not more than 55 degrees, according to the icon display results, determined to be qualified.<br>5.3, motor type test