The horizontal mortar joint of the same plane shall be controlled between 11-15mm, and the mortar filling rate shall be high due to the horizontal and vertical mortar joint, and its fullness shall not be less than 80%. When the mortar laying is adopted, the vertical mortar joint shall be constructed by the combination of batching and adding mortar. In the construction, it is strictly forbidden to use water to flush the mortar to fill the joint, and it is not allowed to use stones, wooden wedges and other construction materials to plug the mortar joint for masonry. During masonry, the surface of the mortar joint should be cleaned along with the masonry, so that the masonry height should not be greater than 4 bricks, and the original mortar joint should be flush with the wall in the pointing process. And the horizontal ash joint shall not be less than 90%, and the vertical ash joint shall not be less than 85%. There shall be no blind joint, crack, transparent joint, etc. in the horizontal and vertical joints during the masonry.<br>