Handling measures for <br>abnormal conditions Abnormal conditions refer to the situation where the vacuum under the membrane cannot reach 80 kPa, or it has fallen after reaching 80 kPa but it is difficult to recover to 80 kPa. There are usually the following reasons: <br>(1) The seal groove leaks, which can go into the groove Irrigation can generally be solved. If it is not possible, mud or clay can be mixed in the water to increase the sealing effect. <br>(2) If the sealing film is damaged, visible small leaks will be repaired immediately. During the pumping process, a chirping sound will be made, and the leaks will be found to remedy. <br>(3) The efficiency of the jet pump is insufficient. Check whether the impeller of the pump is blocked by debris, whether the jet chamber and nozzle are damaged, and keep the jet chamber and the film outlet at the same plane. <br>(4) Leakage at the membrane outlet, re-bundling and sticking with plastic film, and covering with clay. <br>(5) If the sealing film is damaged after covering the water film, a large plastic film can be laid on the hole and covered with silt, and the sand bag is pressurized.