– 300 mA RMS for inverters with rated continuous output power ≤ 30 kVA, or– 10 mA RMS per kVA of rated continuous output power for inverters with rated continuous output power rating > 30 kVA.when tested in accordance with 4.8.3.3.NOTE In the above paragraphs and in the following tests, the current is defined in different ways. The 30 mA limit on touch currents is tested using a human body model touch current test circuit, since that requirement relates to shock hazard. The current limit for fire hazard purposes is measured using a standard ammeter and no human body model circuit because the fire hazard is related to current in an unintended conductor, not current in the human body.