19.6 For all tools where the relevant part 2 requires the tool to be marked with the rated no- load speed, the no-load speed of the spindle at rated voltage or at the upper limit of the rated voltage shall not exceed 110 % of the rated no-load speed.Compliance is checked by measuring the speed of the spindle after the tool has been operating for 5 min at no-load.