equipment and accessories that allow interface of the lighting control system with other systems such as the IBMS and emergency lighting where required, termination of lighting control (data) bus at the Lighting Control Module, termination of incoming and outgoing controlled circuits from final branch circuit panelboard. 1.06 Peripheral system components are deemed to include external signaling sources such as wall stations (manual LV switches), photo electric relays, occupancy sensors and the like. 1.07 Rates for peripheral system components are deemed to include the costs of: outlets, power and control cables, conduits and fittings, from outlet back to upstream power supply unit, auxiliary relay, lighting control (data) bus or lighting control module, fixing and supporting material. 1.08 Network management system is deemed to include: detailed engineering, coordination, manufacture, supply, transportation, delivery, installation, testing, commissioning, setting to work, training and maintenance services for the Network Lighting Control System as described in the Specifications. network management system hardware (servers, workstations, etc…). network management system tools with licensed software. equipment racks/cabinets (except where these are required to be measured separately, for example under Structured Cabling Network), power supply equipment, support, fixation, cable bonding and labelling. cables and connectors and all necessary accessories and other ancillary (Power Distribution Units, and Remote In/Out Control Units…). termination for all signal, control and power circuits, input, and output accessories and connection to power supply point. controls, terminal strips and other components as required for interface and integration with other systems, as described in the Specifications.
equipment and accessories that allow interface of the lighting control system with <br>other systems such as the IBMS and emergency lighting where required, <br>termination of lighting control (data) bus at the Lighting Control Module, <br>termination of incoming and outgoing controlled circuits from final branch circuit <br>panelboard. <br>1.06 Peripheral system components are deemed to include external signaling sources such <br>as wall stations (manual LV switches), photo electric relays, occupancy sensors and <br>the like. <br>1.07 Rates for peripheral system components are deemed to include the costs of: <br>outlets, <br>power and control cables, conduits and fittings, from outlet back to upstream <br>power supply unit, auxiliary relay, lighting control (data) bus or lighting control <br>module, <br>fixing and supporting material. <br>1.08 Network management system is deemed to include: <br>detailed engineering, coordination, manufacture, supply, transportation, delivery, <br>installation, testing, commissioning, setting to work, training and maintenance <br>services for the Network Lighting Control System as described in the <br>Specifications. <br>network management system hardware (servers, workstations, etc…). <br>network management system tools with licensed software. <br>equipment racks/cabinets (except where these are required to be measured <br>separately, for example under Structured Cabling Network), <br>power supply equipment, <br>support, fixation, cable bonding and labelling. <br>cables and connectors and all necessary accessories and other ancillary (Power <br>Distribution Units, and Remote In/Out Control Units…). <br>termination for all signal, control and power circuits, input, and output accessories <br>and connection to power supply point. <br>controls, terminal strips and other components as required for interface and <br>integration with other systems, as described in the Specifications.
正在翻译中..